Brand Name :GYLED
Model Number :GY1331UV40/GY1359UV60
Certification :GB28235;GB19258;Q/141000 GY008—2021
Place of Origin :CHINA
MOQ :10PCS
Price :Negotiation
Payment Terms :T/T, L/C, Western Union
Supply Ability :200000PCS/YEAR
Delivery Time :7-10DAYS
Packaging Details :4PCS/6PCS IN 1CARTON
Rated Power :40W/60W
UV-C Light Type :Philips TUV PL-L UV-C Light
Peak Wavelength :253.7 nm
Light Source Life :10000h
Disinfection Type :Common bacteria, viruses and other microorganisms
Recommended Using Area Dimension :10-20m²
Recommended Filter Replacement Frequency :3-6 months
IP Rating :IP20
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Main Performance and Parameters:

Parameters Items GY1331UV40 GY1359UV60
Rated Power 40W 60W
Input Voltage AC220-240V 50/60 Hz
Power Factor ≥0.9
UV-C Light Type Philips TUV PL-L UV-C Light
Peak Wavelength 253.7 nm
Light Source Life 10000H
Disinfection Type Common bacteria, viruses, and other microorganisms

Recommended Using

Area Dimension

10-15m² 15-20m²
Recommended Filter Replacement Frequency 3-6 months
Working Duration Limit Available for long-term operation
IP Rating IP20
Electric Safety Class CLASS I
Surface Treatment Anti-corrosive powder coating
Dimension 318*133*121mm 638*133*121mm
Net Weight 2.1Kg 3.8Kg
Executive National Standard GB28235;GB19258;Q/141000 GY008—2021

Troubleshooting:

SN Fault Description Cause of Fault Troubleshooting Method
1 The power is on, the indicator light is off, and the fan is working normally UV-C light is damaged Replace with a new UV-C light
2 The power is on, the indicator light is off, and the fan does not work The socket has no electricity, or the product switch is faulty Check whether the socket is electrified. If the socket has electricity, check whether the input circuit such as the product switch is normal
3 The fan noise has increased significantly Too much dust on the filter Replace with a new filter

UV Light Sanitizer UVC Disinfection Lamp Germicidal Lamp Ultraviolet Ozone Steriliser

Safe and effective Air Sterilization Equipment

GY1331UV, GY1359UV Series
Hidden UV-C Air Disinfection Lights

GY1331UV40/GY1359UV60 is the hidden UV-C light series for air disinfection. The product features a broad-spectrum disinfection effect. Tested by the Guangdong Detection Center of Microbiology, its disinfection rate of various types of bacteria, fungi, viruses, and so on, has reached more than 99%.

Sanitizing surfaces is only half of the battle against the spread of bacteria and viruses, That's why hospitals routinely use ultra-violet light technology to disinfect patient areas. The UVC air disinfection is designed to move air around a powerful UV-C light to destroy contaminants in your homes such as allergens, bacteria, germs, mold spores, and viruses that standard HEPA-style air filters often miss.

Features:

1) Appearance design: The overall shape of the product combines two elements: semi-circle and rectangle, with simple, concise, and unrestrained lines. It is suitable for installation in indoor living and studying spaces.

2) Disinfection principle: The product emits UV-C light to irradiate the flowing air, which can inactivate bacteria, viruses, and other microorganisms in the air, thus serving the purpose of disinfection of the air.

3) Hidden UV-C Light: The product adopts a hidden UV-C light structure design in which the UV-C light works in a "closed" metal cavity, ensuring that the UV-C light does not leak so that the product can work for a long time and will not cause harm to people, animals, and indoor objects.

4) Active convection: The product is designed with a fan at one end to introduce indoor air into the disinfection chamber. The air after disinfection by UV-C light flows out from the upper air outlet to the indoor space, with active convection to disinfect the air cycle.

Troubleshooting:

SN Fault Description Cause of Fault Troubleshooting Method
1 The power is on, the indicator light is off, and the fan is working normally UV-C light is damaged Replace with a new UV-C light
2 The power is on, the indicator light is off, and the fan does not work The socket has no electricity, or the product switch is faulty Check whether the socket is electrified. If the socket has electricity, check whether the input circuit such as the product switch is normal
3 The fan noise has increased significantly Too much dust on the filter Replace with a new filter

IP20 Ultraviolet Germicidal Lamp 40W Restaurant Toilet Uv Light Sanitizer

IP20 Ultraviolet Germicidal Lamp 40W Restaurant Toilet Uv Light Sanitizer

IP20 Ultraviolet Germicidal Lamp 40W Restaurant Toilet Uv Light SanitizerIP20 Ultraviolet Germicidal Lamp 40W Restaurant Toilet Uv Light SanitizerIP20 Ultraviolet Germicidal Lamp 40W Restaurant Toilet Uv Light SanitizerIP20 Ultraviolet Germicidal Lamp 40W Restaurant Toilet Uv Light Sanitizer