Add to Cart
Led Uv Light Ultraviolet Lamp Living Room Hotel 40 Watts Led Uv Light Ultraviolet Lamp
Safe and effective Air Sterilization Equipment
GY1331UV, GY1359UV Series
Hidden UV-C Air Disinfection Lights
GY1331UV40/GY1359UV60 is the hidden UV-C light series for air disinfection. The product features a broad-spectrum disinfection effect. Tested by the Guangdong Detection Center of Microbiology, its disinfection rate of various types of bacteria, fungi, viruses, and so on, has reached more than 99%.
HIGH EFFICIENCY STERILIZATION:
This UV-C disinfection lamp achieves 99.99% sterilization (kills 99.99% of germs) by targeting the DNA of microbes, damaging the DNA structure, and preventing their reproduction. It kills Candida albicans, Staphylococcus aureus and Escherichia coli, and works on any surface, and in air or water that is infected by these germs. This device provides sterilization and air purification for spaces under 430 square feet.
Advantages:
Hide the UV-C light source, no harm to people and objects
Active convection of the fan improves the sterilization efficiency and reduces the dead angle
40W and 60W power can provide enough 253.7-nanometer sterilization ultraviolet radiation.
Suitable for air disinfection and purification in daily indoor scenes, long-term work available.
WARNING - Ultraviolet radiation can cause skin and eye burns, please use carefully, according to directions, and heed all warnings. Avoid long-term direct exposure. The process requires people/animals and plants to wait outside during the UVC light cleaning process. After completion, allow at least 60 minutes before humans or animals enter the room.
Main Performance and Parameters:
Parameters Items | GY1331UV40 | GY1359UV60 |
Rated Power | 40 W | 60W |
Input Voltage | AC220-240V 50/60 Hz | |
Power Factor | ≥0.9 | |
UV-C Light Type | Philips TUV PL-L UV-C Light | |
Peak Wavelength | 253.7 nm | |
Light Source Life | 10000H | |
Disinfection Type | Common bacteria, viruses, and other microorganisms | |
Recommended Using Area Dimension | 10-15m² | 15-20m² |
Recommended Filter Replacement Frequency | 3-6 months | |
Working Duration Limit | Available for long-term operation | |
IP Rating | IP20 | |
Electric Safety Class | CLASS I | |
Surface Treatment | Anti-corrosive powder coating | |
Dimension | 318*133*121mm | 638*133*121mm |
Net Weight | 2.1Kg | 3.8Kg |
Executive National Standard | GB28235;GB19258;Q/141000 GY008—2021 |
Features:
1) Appearance design: The overall shape of the product combines two elements: semi-circle and rectangle, with simple, concise, and unrestrained lines. It is suitable for installation in indoor living and studying spaces.
2) Disinfection principle: The product emits UV-C light to irradiate the flowing air, which can inactivate bacteria, viruses, and other microorganisms in the air, thus serving the purpose of disinfection of the air.
3) Hidden UV-C Light: The product adopts a hidden UV-C light structure design in which the UV-C light works in a "closed" metal cavity, ensuring that the UV-C light does not leak so that the product can work for a long time and will not cause harm to people, animals, and indoor objects.
Troubleshooting:
SN | Fault Description | Cause of Fault | Troubleshooting Method |
1 | The power is on, the indicator light is off, and the fan is working normally | UV-C light is damaged | Replace with a new UV-C light |
2 | The power is on, the indicator light is off, and the fan does not work | The socket has no electricity, or the product switch is faulty | Check whether the socket is electrified. If the socket has electricity, check whether the input circuit such as the product switch is normal |
3 | The fan noise has increased significantly | Too much dust on the filter | Replace with a new filter |